Off-Axis Full-Field Time-Domain OCT allows retinal self-scan in the patients with retinal diseases

View Session View Presentation
Add to Schedule Print Abstract

Abstract Number: 1353

AuthorBlock: Claus von der Burchard1, Jan Tode1, Moritz Moltmann2, Christoph Ehlken1, Peter Koch2, Helge Sudkamp2, Malte vom Endt2, Dirk Theisen-Kunde2, Reginald Birngruber2, Gereon Huttmann2, Johann Roider1
1University of Kiel, Germany, Kiel, Germany; 2Medical Laser Center Lübeck, Lübeck, Germany;

DisclosureBlock: Claus von der Burchard, None; Jan Tode, None; Moritz Moltmann, None; Christoph Ehlken, None; Peter Koch, None; Helge Sudkamp, None; Malte vom Endt, None; Dirk Theisen-Kunde, None; Reginald Birngruber, None; Gereon Huttmann, None; Johann Roider, None;

Purpose
Off-Axis Full-Field Time-Domain Optical Coherence Tomography (OA-FF-TD-OCT) is a compact OCT technique that can be produced at a very low-cost. It is a potential candidate for home-care OCT solutions for AMD patients, if the patient can perform the OCT scan reliably by himself. In this study, we introduced AMD patients with typical age and vision to our device. Aim of this study was to measure the success rate of OA-FF-TD-OCT for patient self-assessment and to compare image quality to standard devices.

Methods
In a clinical study, patients with various retinal diseases were placed in front of our OA-FF-TD-OCT device. The patients received a 5-10-minute training in device usage and were then asked to perform a retinal self-scan. This requires the correct alignment of the eye by the patient himself, who can start the measurement by pushing a trigger button. As a reference standard, SD-OCT pictures with a Heidelberg Spectralis OCT were taken.
After acquisition, the images were graded in terms of signal-to-noise ratio, motion artefacts and foveal centering. Only when all of these criteria reached a sufficient score, the picture was marked as “gradable”, i.e. sufficient for determination of disease activity.

Results
51 patients were included in the study (39 AMD patients, 6 patients with diabetic macular edema, 3 patients with retinal vein occlusion, 3 patients with other diseases). Patient age was between 45 and 86 years, visual acuity was between 20/200 and 20/20. After the brief training, 73% of the patients were able to acquire images that were clinically gradable. Failure to acquire sufficient image quality was mainly correlated with higher age, low visual acuity and geographic atrophy. In successful patients, it could be shown that the most relevant biomarkers for AMD (intraretinal fluid, subretinal fluid and pigment epithelium detachment) could be identified with high sensitivity.

Conclusions
OA-FF-TD-OCT allows high-resolution retinal self-scanning by patients with retinal diseases. However, not all patients were able to produce images with sufficient image quality. Further improvement of the patient interface and longer patient training could improve usability, but still, presumably not all patients are suitable candidates.

Layman Abstract (optional): Provide a 50-200 word description of your work that non-scientists can understand. Describe the big picture and the implications of your findings, not the study itself and the associated details.
Off-Axis Full-Field Time-Domain OCT is a low-cost technique that allows patients with retinal diseases to do a self-scan of their retina. This might allow daily self-assessment by the patient at his home. This bears huge potential to improve treatment regimen and thereby improve treatment outcome.